QSFP28 100G Pluggable Transceivers

QSFP28 100G transceivers: SR4, DR1, FR1, CWDM4, PSM4, LR1, LR4, ER4 and ZR4. 100 m multimode to 80 km single-mode.
  • 100G in one QSFP28 port
  • Reach: 100 m (OM4), 500 m, 2 km, 10 km, 40 km and 80 km (single-mode)
  • DR1, FR1 and LR1 connect to one lane of a 400G DR4, DR4+ or DR4++ module
  • MPO-12 (SR4), MPO-12 APC (PSM4) or duplex LC (all other modules)
  • Coding for NVIDIA, Cisco, Juniper, Arista, HPE, Dell, Fortinet, generic or custom
  • Commercial temperature range: 0 °C to +70 °C
  • QSFP28 MSA, SFF-8636 host management

Engineered to Outperform

Delivered with Certainty

Procurement Made Simple

Rapid Deployment Ready

Ready To Scale

Compliance Assured

QSFP28 100G transceivers have 4 electrical lanes at 25G NRZ. Most data centre, campus and carrier switches have QSFP28 ports.

SR4 operates over 100 m of OM4 multimode fibre on one MPO-12 connector. DR1 (500 m), FR1 (2 km) and LR1 (10 km) send 100G on one wavelength. Each of them can connect to one lane of a 400G DR4, DR4+ or DR4++ module through an MPO-to-LC breakout cable.

CWDM4 (2 km) and LR4 (10 km) send 4 wavelengths on one duplex LC connector. PSM4 operates over 2 km or 10 km on an MPO-12 APC connector. You can split a PSM4 link into 4 × 25G. ER4 operates over 40 km. ZR4 operates over 80 km with host FEC. All modules operate from 0 °C to +70 °C.

Coding: each module is listed with NVIDIA (-CN), Cisco (-CC), Juniper (-CJ), Arista (-CA), HPE / Aruba (-CH), Dell (-CD), Fortinet (-CF) and generic (-CG) coding. Custom coding is available on request. The coding changes only the EEPROM identity.

For hyperscale and sovereign compute operators in the Gulf region, including the UAE, Saudi Arabia and Qatar. Use these 100G modules for data centre, campus and metro links from 100 m (multimode) to 80 km (single-mode).
Electrical
Host InterfaceQSFP28 (4 lanes × 25G NRZ)
Signalling4 × 25G NRZ optical (SR4, PSM4, CWDM4, LR4, ER4, ZR4)
1 × 100G PAM4 optical with internal gearbox (DR1, FR1, LR1)
Optical
WavelengthsSR4: 850 nm VCSEL
DR1, PSM4: 1310 nm
FR1, LR1: 1311 nm
CWDM4: 1271 / 1291 / 1311 / 1331 nm
LR4, ER4, ZR4: LAN-WDM 1295.56 / 1300.05 / 1304.58 / 1309.14 nm
ReachSR4: 100 m OM4 (70 m OM3)
DR1: 500 m SMF
FR1, CWDM4: 2 km SMF
PSM4: 2 km or 10 km SMF
LR1, LR4: 10 km SMF
ER4: 40 km SMF
ZR4: 80 km SMF with host RS-FEC enabled, 60 km without
Fibre TypeOM3 / OM4 multimode (SR4)
OS2 single-mode (all other variants)
ConnectorsMPO-12 (SR4)
MPO-12 APC (PSM4)
Duplex LC (DR1, FR1, LR1, CWDM4, LR4, ER4, ZR4)
Media Standards100GBASE-SR4 (IEEE 802.3bm)
100G PSM4 MSA
100GBASE-DR (IEEE 802.3cd)
100GBASE-FR1 / LR1 (IEEE 802.3cu)
100G CWDM4 MSA
100GBASE-LR4 / ER4 (IEEE 802.3ba)
100G ZR4 (industry standard)
Protocol Support
Ethernet100 GbE (all SKUs)
NVIDIA Reference P/NMMA1B00-C100D (SR4)
MMS1V70-CM (DR1)
Coding & Compatibility
Standard CodingsNVIDIA (-CN), Cisco (-CC), Juniper (-CJ), Arista (-CA), HPE / Aruba (-CH), Dell (-CD), Fortinet (-CF), generic (-CG). The optical module is the same for each coding. Only the EEPROM identity is different.
Custom CodingAvailable on request for other switch vendors.
Environmental
Operating Temperature0 °C to +70 °C (Commercial)
Storage Temperature-40 °C to +85 °C
MSA ComplianceQSFP28 MSA
Compliance
StandardsIEEE 802.3ba / 802.3bm / 802.3cd / 802.3cu, CWDM4 MSA, PSM4 MSA, QSFP28 MSA, SFF-8636, RoHS3
RoHS CompliantYes
QSFP28 100G SR4 Multimode (MPO-12)
Part NumberDescription
PO-QS-100GE-SR4-MPO-CNQSFP28 100 GbE SR4, MPO-12, 850 nm, 100 m OM4 / 70 m OM3, 0–70 °C, NVIDIA-coded (ref MMA1B00-C100D)
PO-QS-100GE-SR4-MPO-CCQSFP28 100 GbE SR4, MPO-12, 850 nm, 100 m OM4 / 70 m OM3, 0–70 °C, Cisco-coded
PO-QS-100GE-SR4-MPO-CJQSFP28 100 GbE SR4, MPO-12, 850 nm, 100 m OM4 / 70 m OM3, 0–70 °C, Juniper-coded
PO-QS-100GE-SR4-MPO-CAQSFP28 100 GbE SR4, MPO-12, 850 nm, 100 m OM4 / 70 m OM3, 0–70 °C, Arista-coded
PO-QS-100GE-SR4-MPO-CHQSFP28 100 GbE SR4, MPO-12, 850 nm, 100 m OM4 / 70 m OM3, 0–70 °C, HPE / Aruba-coded
PO-QS-100GE-SR4-MPO-CDQSFP28 100 GbE SR4, MPO-12, 850 nm, 100 m OM4 / 70 m OM3, 0–70 °C, Dell-coded
PO-QS-100GE-SR4-MPO-CFQSFP28 100 GbE SR4, MPO-12, 850 nm, 100 m OM4 / 70 m OM3, 0–70 °C, Fortinet-coded
PO-QS-100GE-SR4-MPO-CGQSFP28 100 GbE SR4, MPO-12, 850 nm, 100 m OM4 / 70 m OM3, 0–70 °C, generic (uncoded)
QSFP28 100G DR1 Single-Lambda (Duplex LC, single-mode)
Part NumberDescription
PO-QS-100GE-DR-LC-CNQSFP28 100 GbE DR1 Single-Lambda, Duplex LC, 1310 nm, 500 m SMF, 0–70 °C, NVIDIA-coded (ref MMS1V70-CM)
PO-QS-100GE-DR-LC-CCQSFP28 100 GbE DR1 Single-Lambda, Duplex LC, 1310 nm, 500 m SMF, 0–70 °C, Cisco-coded
PO-QS-100GE-DR-LC-CJQSFP28 100 GbE DR1 Single-Lambda, Duplex LC, 1310 nm, 500 m SMF, 0–70 °C, Juniper-coded
PO-QS-100GE-DR-LC-CAQSFP28 100 GbE DR1 Single-Lambda, Duplex LC, 1310 nm, 500 m SMF, 0–70 °C, Arista-coded
PO-QS-100GE-DR-LC-CHQSFP28 100 GbE DR1 Single-Lambda, Duplex LC, 1310 nm, 500 m SMF, 0–70 °C, HPE / Aruba-coded
PO-QS-100GE-DR-LC-CDQSFP28 100 GbE DR1 Single-Lambda, Duplex LC, 1310 nm, 500 m SMF, 0–70 °C, Dell-coded
PO-QS-100GE-DR-LC-CFQSFP28 100 GbE DR1 Single-Lambda, Duplex LC, 1310 nm, 500 m SMF, 0–70 °C, Fortinet-coded
PO-QS-100GE-DR-LC-CGQSFP28 100 GbE DR1 Single-Lambda, Duplex LC, 1310 nm, 500 m SMF, 0–70 °C, generic (uncoded)
QSFP28 100G FR1 Single-Lambda (Duplex LC, single-mode)
Part NumberDescription
PO-QS-100GE-FR-LC-CNQSFP28 100 GbE FR1 Single-Lambda, Duplex LC, 1311 nm, 2 km SMF, 0–70 °C, NVIDIA-coded
PO-QS-100GE-FR-LC-CCQSFP28 100 GbE FR1 Single-Lambda, Duplex LC, 1311 nm, 2 km SMF, 0–70 °C, Cisco-coded
PO-QS-100GE-FR-LC-CJQSFP28 100 GbE FR1 Single-Lambda, Duplex LC, 1311 nm, 2 km SMF, 0–70 °C, Juniper-coded
PO-QS-100GE-FR-LC-CAQSFP28 100 GbE FR1 Single-Lambda, Duplex LC, 1311 nm, 2 km SMF, 0–70 °C, Arista-coded
PO-QS-100GE-FR-LC-CHQSFP28 100 GbE FR1 Single-Lambda, Duplex LC, 1311 nm, 2 km SMF, 0–70 °C, HPE / Aruba-coded
PO-QS-100GE-FR-LC-CDQSFP28 100 GbE FR1 Single-Lambda, Duplex LC, 1311 nm, 2 km SMF, 0–70 °C, Dell-coded
PO-QS-100GE-FR-LC-CFQSFP28 100 GbE FR1 Single-Lambda, Duplex LC, 1311 nm, 2 km SMF, 0–70 °C, Fortinet-coded
PO-QS-100GE-FR-LC-CGQSFP28 100 GbE FR1 Single-Lambda, Duplex LC, 1311 nm, 2 km SMF, 0–70 °C, generic (uncoded)
QSFP28 100G CWDM4 (Duplex LC, single-mode)
Part NumberDescription
PO-QS-100GE-CW4-LC-CNQSFP28 100 GbE CWDM4, Duplex LC, 1271–1331 nm, 2 km SMF, 0–70 °C, NVIDIA-coded
PO-QS-100GE-CW4-LC-CCQSFP28 100 GbE CWDM4, Duplex LC, 1271–1331 nm, 2 km SMF, 0–70 °C, Cisco-coded
PO-QS-100GE-CW4-LC-CJQSFP28 100 GbE CWDM4, Duplex LC, 1271–1331 nm, 2 km SMF, 0–70 °C, Juniper-coded
PO-QS-100GE-CW4-LC-CAQSFP28 100 GbE CWDM4, Duplex LC, 1271–1331 nm, 2 km SMF, 0–70 °C, Arista-coded
PO-QS-100GE-CW4-LC-CHQSFP28 100 GbE CWDM4, Duplex LC, 1271–1331 nm, 2 km SMF, 0–70 °C, HPE / Aruba-coded
PO-QS-100GE-CW4-LC-CDQSFP28 100 GbE CWDM4, Duplex LC, 1271–1331 nm, 2 km SMF, 0–70 °C, Dell-coded
PO-QS-100GE-CW4-LC-CFQSFP28 100 GbE CWDM4, Duplex LC, 1271–1331 nm, 2 km SMF, 0–70 °C, Fortinet-coded
PO-QS-100GE-CW4-LC-CGQSFP28 100 GbE CWDM4, Duplex LC, 1271–1331 nm, 2 km SMF, 0–70 °C, generic (uncoded)
QSFP28 100G PSM4 (MPO-12 APC, parallel single-mode)
Part NumberDescription
PO-QS-100GE-PSM4K2-MPO-CNQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G parallel, 2 km SMF, 0–70 °C, NVIDIA-coded
PO-QS-100GE-PSM4K2-MPO-CCQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G parallel, 2 km SMF, 0–70 °C, Cisco-coded
PO-QS-100GE-PSM4K2-MPO-CJQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G parallel, 2 km SMF, 0–70 °C, Juniper-coded
PO-QS-100GE-PSM4K2-MPO-CAQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G parallel, 2 km SMF, 0–70 °C, Arista-coded
PO-QS-100GE-PSM4K2-MPO-CHQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G parallel, 2 km SMF, 0–70 °C, HPE / Aruba-coded
PO-QS-100GE-PSM4K2-MPO-CDQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G parallel, 2 km SMF, 0–70 °C, Dell-coded
PO-QS-100GE-PSM4K2-MPO-CFQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G parallel, 2 km SMF, 0–70 °C, Fortinet-coded
PO-QS-100GE-PSM4K2-MPO-CGQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G parallel, 2 km SMF, 0–70 °C, generic (uncoded)
PO-QS-100GE-PSM4K10-MPO-CNQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G parallel, 10 km SMF, 0–70 °C, NVIDIA-coded
PO-QS-100GE-PSM4K10-MPO-CCQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G parallel, 10 km SMF, 0–70 °C, Cisco-coded
PO-QS-100GE-PSM4K10-MPO-CJQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G parallel, 10 km SMF, 0–70 °C, Juniper-coded
PO-QS-100GE-PSM4K10-MPO-CAQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G parallel, 10 km SMF, 0–70 °C, Arista-coded
PO-QS-100GE-PSM4K10-MPO-CHQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G parallel, 10 km SMF, 0–70 °C, HPE / Aruba-coded
PO-QS-100GE-PSM4K10-MPO-CDQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G parallel, 10 km SMF, 0–70 °C, Dell-coded
PO-QS-100GE-PSM4K10-MPO-CFQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G parallel, 10 km SMF, 0–70 °C, Fortinet-coded
PO-QS-100GE-PSM4K10-MPO-CGQSFP28 100 GbE PSM4, MPO-12 APC, 1310 nm, 4 × 25G parallel, 10 km SMF, 0–70 °C, generic (uncoded)
QSFP28 100G LR1 Single-Lambda (Duplex LC, single-mode)
Part NumberDescription
PO-QS-100GE-LR-LC-CNQSFP28 100 GbE LR1 Single-Lambda, Duplex LC, 1311 nm, 10 km SMF, 0–70 °C, NVIDIA-coded
PO-QS-100GE-LR-LC-CCQSFP28 100 GbE LR1 Single-Lambda, Duplex LC, 1311 nm, 10 km SMF, 0–70 °C, Cisco-coded
PO-QS-100GE-LR-LC-CJQSFP28 100 GbE LR1 Single-Lambda, Duplex LC, 1311 nm, 10 km SMF, 0–70 °C, Juniper-coded
PO-QS-100GE-LR-LC-CAQSFP28 100 GbE LR1 Single-Lambda, Duplex LC, 1311 nm, 10 km SMF, 0–70 °C, Arista-coded
PO-QS-100GE-LR-LC-CHQSFP28 100 GbE LR1 Single-Lambda, Duplex LC, 1311 nm, 10 km SMF, 0–70 °C, HPE / Aruba-coded
PO-QS-100GE-LR-LC-CDQSFP28 100 GbE LR1 Single-Lambda, Duplex LC, 1311 nm, 10 km SMF, 0–70 °C, Dell-coded
PO-QS-100GE-LR-LC-CFQSFP28 100 GbE LR1 Single-Lambda, Duplex LC, 1311 nm, 10 km SMF, 0–70 °C, Fortinet-coded
PO-QS-100GE-LR-LC-CGQSFP28 100 GbE LR1 Single-Lambda, Duplex LC, 1311 nm, 10 km SMF, 0–70 °C, generic (uncoded)
QSFP28 100G LR4 (Duplex LC, single-mode)
Part NumberDescription
PO-QS-100GE-LR4-LC-CNQSFP28 100 GbE LR4, Duplex LC, LAN-WDM 1295–1310 nm, 10 km SMF, 0–70 °C, NVIDIA-coded
PO-QS-100GE-LR4-LC-CCQSFP28 100 GbE LR4, Duplex LC, LAN-WDM 1295–1310 nm, 10 km SMF, 0–70 °C, Cisco-coded
PO-QS-100GE-LR4-LC-CJQSFP28 100 GbE LR4, Duplex LC, LAN-WDM 1295–1310 nm, 10 km SMF, 0–70 °C, Juniper-coded
PO-QS-100GE-LR4-LC-CAQSFP28 100 GbE LR4, Duplex LC, LAN-WDM 1295–1310 nm, 10 km SMF, 0–70 °C, Arista-coded
PO-QS-100GE-LR4-LC-CHQSFP28 100 GbE LR4, Duplex LC, LAN-WDM 1295–1310 nm, 10 km SMF, 0–70 °C, HPE / Aruba-coded
PO-QS-100GE-LR4-LC-CDQSFP28 100 GbE LR4, Duplex LC, LAN-WDM 1295–1310 nm, 10 km SMF, 0–70 °C, Dell-coded
PO-QS-100GE-LR4-LC-CFQSFP28 100 GbE LR4, Duplex LC, LAN-WDM 1295–1310 nm, 10 km SMF, 0–70 °C, Fortinet-coded
PO-QS-100GE-LR4-LC-CGQSFP28 100 GbE LR4, Duplex LC, LAN-WDM 1295–1310 nm, 10 km SMF, 0–70 °C, generic (uncoded)
QSFP28 100G ER4 (Duplex LC, single-mode)
Part NumberDescription
PO-QS-100GE-ER4-LC-CNQSFP28 100 GbE ER4, Duplex LC, LAN-WDM 1295–1310 nm, 40 km SMF, 0–70 °C, NVIDIA-coded
PO-QS-100GE-ER4-LC-CCQSFP28 100 GbE ER4, Duplex LC, LAN-WDM 1295–1310 nm, 40 km SMF, 0–70 °C, Cisco-coded
PO-QS-100GE-ER4-LC-CJQSFP28 100 GbE ER4, Duplex LC, LAN-WDM 1295–1310 nm, 40 km SMF, 0–70 °C, Juniper-coded
PO-QS-100GE-ER4-LC-CAQSFP28 100 GbE ER4, Duplex LC, LAN-WDM 1295–1310 nm, 40 km SMF, 0–70 °C, Arista-coded
PO-QS-100GE-ER4-LC-CHQSFP28 100 GbE ER4, Duplex LC, LAN-WDM 1295–1310 nm, 40 km SMF, 0–70 °C, HPE / Aruba-coded
PO-QS-100GE-ER4-LC-CDQSFP28 100 GbE ER4, Duplex LC, LAN-WDM 1295–1310 nm, 40 km SMF, 0–70 °C, Dell-coded
PO-QS-100GE-ER4-LC-CFQSFP28 100 GbE ER4, Duplex LC, LAN-WDM 1295–1310 nm, 40 km SMF, 0–70 °C, Fortinet-coded
PO-QS-100GE-ER4-LC-CGQSFP28 100 GbE ER4, Duplex LC, LAN-WDM 1295–1310 nm, 40 km SMF, 0–70 °C, generic (uncoded)
QSFP28 100G ZR4 (Duplex LC, single-mode)
Part NumberDescription
PO-QS-100GE-ZR4-LC-CNQSFP28 100 GbE ZR4, Duplex LC, LAN-WDM 1295–1310 nm, 80 km SMF with host RS-FEC (60 km without), 0–70 °C, NVIDIA-coded
PO-QS-100GE-ZR4-LC-CCQSFP28 100 GbE ZR4, Duplex LC, LAN-WDM 1295–1310 nm, 80 km SMF with host RS-FEC (60 km without), 0–70 °C, Cisco-coded
PO-QS-100GE-ZR4-LC-CJQSFP28 100 GbE ZR4, Duplex LC, LAN-WDM 1295–1310 nm, 80 km SMF with host RS-FEC (60 km without), 0–70 °C, Juniper-coded
PO-QS-100GE-ZR4-LC-CAQSFP28 100 GbE ZR4, Duplex LC, LAN-WDM 1295–1310 nm, 80 km SMF with host RS-FEC (60 km without), 0–70 °C, Arista-coded
PO-QS-100GE-ZR4-LC-CHQSFP28 100 GbE ZR4, Duplex LC, LAN-WDM 1295–1310 nm, 80 km SMF with host RS-FEC (60 km without), 0–70 °C, HPE / Aruba-coded
PO-QS-100GE-ZR4-LC-CDQSFP28 100 GbE ZR4, Duplex LC, LAN-WDM 1295–1310 nm, 80 km SMF with host RS-FEC (60 km without), 0–70 °C, Dell-coded
PO-QS-100GE-ZR4-LC-CFQSFP28 100 GbE ZR4, Duplex LC, LAN-WDM 1295–1310 nm, 80 km SMF with host RS-FEC (60 km without), 0–70 °C, Fortinet-coded
PO-QS-100GE-ZR4-LC-CGQSFP28 100 GbE ZR4, Duplex LC, LAN-WDM 1295–1310 nm, 80 km SMF with host RS-FEC (60 km without), 0–70 °C, generic (uncoded)